Cable lugs, where used as connectors, shall provide electrical contact. Pressure regulators, including associated gauges, shall be maintained in safe working order. 1926 Subpart S App A - Decompression Tables. 0000052058 00000 n 1926.650 - Scope, application, and definitions applicable to this subpart. HOT WORK SAFETY GUIDE . 1926.1213 - Provision of documents to Secretary. 0000006757 00000 n Input power terminals, top change devices and live metal parts connected to imput circuits shall be enclosed and accessible only by means of insulated tools. If the object to be welded or cut cannot readily be moved, all movable fire hazards in the vicinity shall be taken to a safe place. "Hot work" means riveting, welding, flame cutting or other fire or spark-producing operation. No person other than the gas supplier shall attempt to mix gases in a cylinder. 1926.1407 - Power line safety (up to 350 kV)assembly and disassembly. When you edit your document, you may need to add text, put on the date, and do other editing. They shall not be intentionally dropped, struck, or permitted to strike each other violently. 1926.1419 - Signalsgeneral requirements. The basic precautions for fire prevention in welding or cutting work are: 1910.252 (a) (1) (i) Fire hazards. 0000028894 00000 n For welding, cutting and heating on steel pipelines containing natural gas, the pertinent portions of regulations issued by the Department of Transportation, Office of Pipeline Safety, 49 CFR part 192, Minimum Federal Safety Standards for Gas Pipelines, shall apply. Ventilation requirements depend on the metals and compounds used. Oil and grease hazards. (This action is generally termed "cracking" and is intended to clear the valve of dust or dirt that might otherwise enter the regulator.) 1926.350 (a) (1) Valve protection caps shall be in place and secured. Fuel gas shall not be used from cylinders through torches or other devices which are equipped with shutoff valves without reducing the pressure through a suitable regulator attached to the cylinder valve or manifold. 1926.1408 - Power line safety (up to 350 kV)equipment operations. Electrodes shall not be struck against a cylinder to strike an arc. 1926.858 - Removal of steel construction. The permit acts as a checklist to ensure precautions are taken to prevent the ignition of inflammable or combustible materials in a 35-foot area surrounding the work. Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance. When cylinders are hoisted, they shall be secured on a cradle, slingboard, or pallet. 6, 1979, as amended at 55 FR 42328, Oct. 18, 1990; 58 FR 35179, June 30, 1993], Occupational Safety & Health Administration. 1926.432 - Environmental deterioration of equipment. Any employee who enters the space, or that employee's authorized representative, must be provided an opportunity to observe the pre-entry testing required by this paragraph. This type of work can include welding, flame cutting, grinding, soldering, brazing and other activities that have the potential to cause fires or explosions. 1926.958 - Materials handling and storage. a. OSHA amended 29 CFR Part 1960 to implement its "Multi-Employer Worksite Policy" in the federal sector, as stated in 60 Federal Register (FR) 35040. Before entry operations begin, the host employer must provide the following information, if it has it, to the controlling contractor: The hazards or potential hazards in each space or the reason it is a permit space; and. 1926.758 - Systems-engineered metal buildings. %PDF-1.7 % Hose subjected to flashback or showing evidence of severe wear or damage shall be tested to twice the normal working pressure but not less than 200 p.s.i. Ventilation and employee protection in welding, cutting and heating -. 1926.104 - Safety belts, lifelines, and lanyards. @0 CP KkW@M | Rd~3wO`;Kvn5wse>Ed}< E]GN6p:K}qc[uvB_ks1WeO.){}4WKicZjz.,vK`nRQWxyKf!Krd^W`Og37wr6S5BMP_/JVp 0 Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried. osha hot work permit requirements 1926; hot work permit checklist; hot work hazards and control measures pdf; sample hot work permit for cutting or welding; How to Edit Your Hot Work Permit Osha Standard Online. 1926.61 - Retention of DOT markings, placards and labels. If a regulator attached to a valve stops a leak, the cylinder need not be removed from the workplace but shall be tagged and may not be used again before it is repaired; and. No one shall use a cylinder's contents for purposes other than those intended by the supplier. 1926.1414 - Wire ropeselection and installation criteria. The Hot Work Permit is key to managing hot and preventing fires. 1926.913 - Blasting in excavation work under compressed air. Grounding circuits shall have resistance low enough to permit sufficient current to flow to cause the fuse or circuit breaker to interrupt the current. 1926 Subpart R App D - Illustration of the Use of Control Lines To Demarcate Controlled Decking Zones (CDZs): Non-mandatory Guidelines for Complying With 1926.760(c)(3). Oxygen and fuel gas pressure regulators, including their related gauges, shall be in proper working order while in use. Occupational Safety & Health Administration, Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance. 1926.352 (b) 1926.33 - Access to employee exposure and medical records. 1926.1127 App A - Substance Safety Data Sheet - Cadmium, 1926.1127 App B - Substance Technical Guidelines for Cadmium, 1926.1127 App C - Qualitative and Quantitative Fit Testing Procedures, 1926.1127 App D - Occupational Health History Interview With Reference to Cadmium Exposure, 1926.1127 App E - Cadmium in Workplace Atmospheres, 1926.1127 App F - Nonmandatory Protocol for Biological Monitoring. The permit shall document that the fire prevention and protection requirements in 29 CFR 1910.252 (a) have been implemented prior to beginning the hot work operations, indicate the date (s) authorized for hot work, and identify the object on which hot work is to be performed (68.85). 1926.1211 - Rescue and emergency services. 1926 Subpart D - Occupational Health and Environmental Controls. Fuel gas cylinders shall be placed with valve end up whenever they are in use. The results of tests and monitoring performed under 1926.1204(e), accompanied by the names or initials of the testers and by an indication of when the tests were performed; The rescue and emergency services that can be summoned and the means (such as the equipment to use and the numbers to call) for summoning those services; The communication procedures used by authorized entrants and attendants to maintain contact during the entry; Equipment, such as personal protective equipment, testing equipment, communications equipment, alarm systems, and rescue equipment, to be provided for compliance with this standard; Any other information necessary, given the circumstances of the particular confined space, to ensure employee safety; and. 1926.1404 - Assembly/Disassemblygeneral requirements (applies to all assembly and disassembly operations). If, when the valve on a fuel gas cylinder is opened, there is found to be a leak around the valve stem, the valve shall be closed and the gland nut tightened. The atmosphere within the space must be continuously monitored unless the entry employer can demonstrate that equipment for continuous monitoring is not commercially available or periodic monitoring is sufficient. Hoses, cables, and other equipment shall be kept clear of passageways, ladders and stairs. English 02/15/2023 . Any special wrench required for emergency closing shall be positioned on the valve stem during cylinder use. Before entry operations begin, the controlling contractor must: Obtain the host employer's information about the permit space hazards and previous entry operations; and. 0000013825 00000 n Hose connections shall be kept free of grease and oil. 0000052089 00000 n Surfaces prepared with chlorinated solvents shall be thoroughly dry before welding is performed on them. 1926.703 - Requirements for cast-in-place Concrete. To the extent possible, hot work shall be performed in designated locations that are free of fire hazards. The United States Occupational Safety and Health Administration (OSHA) incorporated NFPA 51B by reference at 29 CFR 1910.252. . Yes, permits for performing hot work are required by both OSHA and the National Fire Protection Association (NFPA), in addition to the local fire code. A copy of the contractor's written Hot Work Permit Procedures shall be available for EH&S review. 1926.55 - Gases, vapors, fumes, dusts, and mists. 1926.60 App A - Substance Data Sheet, for 4-4'-METHYLENEDIANILINE, 1926.60 App B - Substance Technical Guidelines, MDA, 1926.60 App C - Medical Surveillance Guidelines for MDA, 1926.60 App D - Sampling and Analytical Methods for MDA Monitoring and Measurement Procedures. Communications. Employees exposed to radiation shall have their skin covered completely to prevent ultraviolet burns and damage. 1926.107 - Definitions applicable to this subpart. 29 CFR 1910.146 Permit Required - Confined Spaces; 29 CFR 1926.1206 Confined Spaces in Construction Training. Note to paragraph (h). CHAPTER XVII - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR PART 1926 - SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Subpart F - Fire Protection and Prevention 29 CFR Subpart F - Fire Protection and Prevention CFR prev | next 1926.150 Fire protection. Getting a hot work permit before performing hot work is just one of steps involved in a hot work . USA Distributor of MCM Equipment osha hot work permit requirements 1926 1926.22 - Recording and reporting of injuries. 1926.705 - Requirements for lift-slab construction operations. 0000006146 00000 n 1926 Subpart L App D - List of Training Topics for Scaffold Erectors and Dismantlers. If it is necessary to enter the permit space to eliminate or isolate hazards, such entry must be performed under 1926.1204 through 1926.1211. 0000052551 00000 n 1926.417 - Lockout and tagging of circuits. Torches in use shall be inspected at the beginning of each working shift for leaking shutoff valves, hose couplings, and tip connections. Structures or pipelines acting continuously as ground return circuits shall have joints bonded and maintained to ensure that no electrolysis or fire hazard exists. 0000000016 00000 n Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. 1926.13 - Interpretation of statutory terms. Welding & cutting operations, conducted outside authorized hot work areas, includes extensive procedures for fire prevention. Hit the arrow with the inscription Next to move from field to field. If continuous monitoring is not used, periodic monitoring is required. 0000015110 00000 n Welding, cutting or heating of toxic metals. Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Severe Storm and Flood Recovery Assistance. 1926.902 - Surface transportation of explosives. Before an employee enters the space, the internal atmosphere must be tested, with a calibrated direct-reading instrument, for oxygen content, for flammable gases and vapors, and for potential toxic air contaminants, in that order. If continuous monitoring is used, the employer must ensure that the monitoring equipment has an alarm that will notify all entrants if a specified atmospheric threshold is achieved, or that an employee will check the monitor with sufficient frequency to ensure that entrants have adequate time to escape. The employer must implement measures to protect employees from the hazard before any subsequent entry takes place. |_W+ All hose in use, carrying acetylene, oxygen, natural or manufactured fuel gas, or any gas or substance which may ignite or enter into combustion, or be in any way harmful to employees, shall be inspected at the beginning of each working shift. Defective hose shall be removed from service. Any precautions that the host employer or any previous controlling contractor or entry employer implemented for the protection of employees in the permit space. Hose couplings shall not unlock or disconnect without rotary motion. 1926.502 - Fall protection systems criteria and practices. They shall not be hoisted or transported by means of magnets or choker slings. Note to paragraph (i). 1926.1406 - Assembly/Disassemblyemployer procedures--general requirements. Create this form in 5 minutes! Operational precaution. Hot Work permit Every job site involving Hot Work requires a permit to document the hazards and the safeguards in place to ensure the planned hot work does not cause a fire. Contractors are required to ensure compliance with applicable federal, state and local regulations as well as any specific requirements that are set in place by Cornell University. Fuel gas and oxygen manifolds shall bear the name of the substance they contain in letters at least 1-inch high which shall be either painted on the manifold or on a sign permanently attached to it. hot work training. Ground connections shall be mechanically and electrically adequate to carry the current. 0000036037 00000 n For the elimination of possible fire in enclosed spaces as a result of gas escaping through leaking or improperly closed torch valves, the gas supply to the torch shall be positively shut off at some point outside the enclosed space whenever the torch is not to be used or whenever the torch is left unattended for a substantial period of time, such as during the lunch period. Shall have valve protection caps in place except when in use, hooked up or secured for movement. 1926.97 - Electrical protective equipment. When there are changes in the use or configuration of a non-permit confined space that might increase the hazards to entrants, or some indication that the initial evaluation of the space may not have been adequate, each entry employer must have a competent person reevaluate that space and, if necessary, reclassify it as a permit-required confined space. For manifolded or coupled cylinders, at least one wrench shall be immediately available. 1926.1153 App A - Methods of Sample Analysis, 1926.1153 App B - Medical Surveillance Guidelines, 1926 Subpart AA - Confined Spaces in Construction. If there is no controlling contractor present at the worksite, the requirements for, and role of, controlling contactors in this section must be fulfilled by the host employer or other employer who arranges to have employees of another employer perform work that involves permit space entry. Oxygen shall not be used for ventilation, cooling or cleaning clothing or work areas. Bars shall not be used under valves or valve protection caps to pry cylinders loose when frozen. Continuous forced air ventilation must be used, as follows: An employee must not enter the space until the forced air ventilation has eliminated any hazardous atmosphere; The forced air ventilation must be so directed as to ventilate the immediate areas where an employee is or will be present within the space and must continue until all employees have left the space; The air supply for the forced air ventilation must be from a clean source and must not increase the hazards in the space. Unless cylinders are firmly secured on a special carrier intended for this purpose, regulators shall be removed and valve protection caps put in place before cylinders are moved. Note to paragraph (d). When this is impractical, fire resistant shields shall be provided. In the U.S., the Occupational Safety and Health Administration (OSHA) is the source of many rules and guidelines intended to protect workers from job-related hazards across virtually all industries. Ask how long hot work permits are valid. Oregon OSHA provides a variety of publications, including; guide books, brochures, forms, hazard alerts, fact sheets, posters, cards, stickers, reports, and checklists on a variety of workplace health and safety topics. 1926.703 App - General Requirements for Formwork. 0000009221 00000 n Oxygen cylinders and fittings shall be kept away from oil or grease. Welding, cutting and heating on preservative coatings. 350 - 354) Welding, Cutting and Soldering Safety (Hot Work) (Standard Operating Procedure) Purpose . Includes how employers must control respiratory hazards in the space; testing the internal atmosphere; and what to document for each entry. Only cable free from repair or splice for 10 feet (3 m) from the electrode holder shall be used unless insulated connectors or splices with insulating quality equal to that of the cable are provided. 4. 0000016958 00000 n The precautions that the host employer, controlling contractor, or other entry employers implemented for the protection of employees in the permit spaces.